ARTG30LHTA
Product Category High Static Single Phase
Product Range High Static Single Phase range
Capacity 9.00kW Cooling 11.20kW Heating
Model Number ARTG30LHTA

Technical Specifications

Indoor unit ARTG30LHTA
Outdoor unit AOTG30LATL
Operation Type Reverse Cycle
Power Source V/Ph/Hz 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max)) 9.00 (4.7 - 10.0)
Heating Capacity kW (Rated (Min - Max)) 11.20 (5.0 - 12.1)
Input Power Cooling kW (Rated (Max)) 2.7 (4.3)
Input Power Heating kW (Rated (Max)) 2.95 (4.3)
EER Cooling kW/kW 3.33
COP Heating kW/kW 3.8
Star Rating Cooling (0-10) (Hot / Average / Cold) 3 / 2.5 / 2.5
Star Rating Heating (0-10) (Hot / Average / Cold) 2.5 / 2 / 2
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.585 / 4.248 / 4.407
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.364 / 3.973 / 3.526
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.924 / 5.019 / 5.365
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.362 / 4.122 / 3.746
Running Current amps (Cooling / Heating) 11.4 / 12.4
Moisture Removal l/hr 1.0
Indoor Sound Pressure Cooling dBA (High / Low) 41 / 36
Indoor Sound Pressure Heating dBA (High / Low) 41 / 36
Outdoor Sound Pressure dBA (Cooling / Heating) 52 / 53
Outdoor Sound Power dBA 67
Static Pressure Range PA (Min to Max) 60 to 210
Air Circulation (Indoor - High Fan) Cooling l/sec 695
Air Circulation (Indoor - High Fan) Heating l/sec 695
Indoor Unit Dimensions mm (Height x Width x Depth) 400 x 1050 x 500
Indoor Unit Weight kg 39.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 1290 x 900 x 330
Outdoor Unit Weight kg 86.00
Piping Connects mm Ø (Liquid / Gas) 9.52 / 15.88
Pipe Length m (Max (Precharged)) 50 (20)
Max Height Difference m 30
Operation Range Cooling °CDB (Min to Max) -5 to 46
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Type R410A
Refrigerant Amount g 3,350

Dimensions

What’s included in your purchase

ARTG30LHTA

ARTG30LHTA

Indoor Unit

AOTG30LATL

Outdoor Unit

UTY-RVNYN

UTY-RVNYN

Wired Remote Controller - Backlit Wired Controller

Optional Parts

UTY-ANY1

WiFi Control - anywAiR Technology Ducted Controller

UTY-CDPXZC

Zone Control Interface Module - 8 Zones, 24V

UTY-CDPXZD

Zone Control Interface Module - 8 Zones, 240V

UTY-RNNYN

UTY-RNNYN

Wired Remote Controller

UTY-RSNYN

UTY-RSNYN

Wired Remote Controller - Simple Controller With Mode Button

UTD-ECS5A

External Control Wiring Kit

UTY-XWZXZ3

External Connect Kit

Key features

High static air conditioning allows for an increased number of air ducts to be installed and the single phase power allows for greater installation flexibility.

  • Zone Control
    Zone Control

    This function enables efficient air-conditioning by selecting specific zones from the various zones divided within the indoor space.

  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Connectable Distribution Duct
    Connectable Distributing Duct

    Systems are capable of attaching a field-supplied branch ducts distributing the airflow.

  • Connectable Fresh Air Duct
    Connectable Fresh Air Duct

    Allows introduction of fresh air to the occupied space.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Filter Sign
    Filter Sign

    Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

Operating Manual

Click on the Download button below to get the pdf

Download PDF