Infinity Range Header
Available in Reverse Cycle - 15.8kW
Refrigerant R410A

Key features

  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Connectable Distribution Duct
    Connectable Distributing Duct

    Systems are capable of attaching a field-supplied branch ducts distributing the airflow.

  • Connectable Fresh Air Duct
    Connectable Fresh Air Duct

    Allows introduction of fresh air to the occupied space.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Filter Sign
    Filter Sign

    Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.

  • Fresh Air Intake
    Fresh Air Intake

    Fresh air can be taken in by a fan which can be connected using an external control unit.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

  • Automatic Air Flow Adjustment
    Automatic Air Flow Adjustment

    The micro-processor automatically adjusts the air flow to follow changes in room temperature.

  • Zone Control
    Zone Control

    This function enables efficient air-conditioning by selecting specific zones from the various zones divided within the indoor space.

Take control. Controller options.

This range is compatible with the following controller options.

  • controller-feature tick
    Backlit Display

    An illuminated display for improved visibiltiy and clairty. Brightness and light duration can be customised to suit your preferences.

  • controller-feature tick
    Set Temperature Auto Return

    The set temperature automatically returns to the previous set temperature at the touch of a button.

  • controller-feature tick
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

Find the perfect model. Explore the High Static Next Gen range.

Technical Specifications

Attribute ARTG60LDTA 15.80kW(C) 18.00kW(H) View model
Operation Type
Reverse Cycle
Power Source V/Ph/Hz
240 / 1 / 50
Cooling Capacity kW (Rated (Min - Max))
15.80 (6.2 - 16.3)
Heating Capacity kW (Rated (Min - Max))
18.00 (6.2 - 18.5)
Input Power Cooling kW (Rated (Max))
4.92 (6.15)
Input Power Heating kW (Rated (Max))
4.99 (6.18)
EER Cooling kW/kW
3.21
COP Heating kW/kW
3.61
Star Rating Cooling (0-10) (Hot / Average / Cold)
2.5 / 2.5 / 2.5
Star Rating Heating (0-10) (Hot / Average / Cold)
2.5 / 1.5 / 1.0
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.239 / 4.025 / 4.183
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.061 / 3.247 / 2.78
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.508 / 4.594 / 4.902
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.056 / 3.603 / 3.031
Running Current amps (Cooling / Heating)
20.7 / 21.0
Moisture Removal l/hr
2.1
Indoor Sound Pressure Cooling dBA (High / Quiet)
44 / 35
Indoor Sound Pressure Heating dBA (High / Quiet)
44 / 35
Outdoor Sound Pressure dBA (Cooling / Heating)
57 / 59
Outdoor Sound Power dBA
72
Static Pressure Range PA (Min to Max)
60 to 250
Air Circulation (Indoor - High Fan) Cooling l/sec
1139
Air Circulation (Indoor - High Fan) Heating l/sec
1139
Indoor Unit Dimensions mm (Height x Width x Depth)
-
Indoor Unit Weight kg
69.00
Outdoor Unit Dimensions mm (Height x Width x Depth)
1290 x 900 x 330
Outdoor Unit Weight kg
97.00
Piping Connects mm Ø (Liquid / Gas)
9.52 / 15.88
Pipe Length m (Max (Precharged))
75 (30)
Max Height Difference m
30
Operation Range Cooling °CDB (Min to Max)
-15 to 46
Operation Range Heating °CDB (Min to Max)
-15 to 24
Refrigerant Type
R410A
Refrigerant Amount g
4,500

Why Choose Fujitsu

why-choose-fujitsu-warranty 2
Peace of mind

Purchase from a Fujitsu accredited installer and receive a full 6 year warranty.

Explore now
why-choose-fujitsu-trustedbrand 2
A brand you can trust

Voted by New Zealanders as a trusted brand in the heat pump category.

Explore now
Breathe Easy
Breathe Easy

Fujitsu General New Zealand is recommended by Asthma New Zealand.

Explore now
Sensitive choice
Sensitive Choice

Fujitsu’s advanced filter systems contribute to a fresher and cleaner living environment. 

Explore now

Find where to buy a Fujitsu Heat Pump / Air Conditioner

We have a comprehensive network of Fujitsu Accredited Installers right across New Zealand to ensure that there is a local stockist in your area to assist you wherever you are.

map-icon-white Find a Stockist