AGTV0914LAC
Product Category Floor/Ceiling Consoles
Product Range Floor Console range
Capacity 2.60kW Cooling 3.50kW Heating
Model Number AGTV09LAC
Room Size Small Room

Technical Specifications

Indoor unit AGTV09LAC
Outdoor unit AOTV09LAC
Operation Type Reverse Cycle
Power Source V/Ph/Hz 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max)) 2.60 (0.9 - 3.5)
Heating Capacity kW (Rated (Min - Max)) 3.50 (0.9 - 5.5)
Input Power Cooling kW (Rated (Min - Max)) 0.60 (0.15 - 1.40)
Input Power Heating kW (Rated (Min - Max)) 0.81 (0.25 - 2.20)
EER Cooling kW/kW 4.33
COP Heating kW/kW 4.32
Star Rating Cooling (0-10) (Hot / Average / Cold) 4.5 / 3.0 / 3.0
Star Rating Heating (0-10) (Hot / Average / Cold) 3.5 / 3.0 / 2.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 6.121 / 4.794 / 4.706
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 5.182 / 4.689 / 4.221
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 7.257 / 7.206 / 8.096
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 5.185 / 4.886 / 4.476
Running Current amps (Cooling / Heating) 2.8 / 3.8
Moisture Removal l/hr 1.3
Indoor Sound Pressure Cooling dBA (High / Quiet) 40 / 22
Indoor Sound Pressure Heating dBA (High / Quiet) 40 / 22
Outdoor Sound Pressure dBA (Cooling / Heating) 47 / 48
Outdoor Sound Power dBA 64
Air Circulation (Indoor - High Fan) Cooling l/sec 570
Air Circulation (Indoor - High Fan) Heating l/sec 600
Indoor Unit Dimensions mm (Height x Width x Depth) 600 x 740 x 200
Indoor Unit Weight kg 14.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 540 x 790 x 290
Outdoor Unit Weight kg 36.00
Piping Connects mm Ø (Liquid / Gas) 6.35 / 9.52
Pipe Length m (Max (Precharged)) 20 (15)
Max Height Difference m 15
Operation Range Cooling °CDB (Min to Max) -10 to 43
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Type R410A
Refrigerant Amount g 1,050

Dimensions

What’s included in your purchase

AGTV0914LAC

AGTV09LAC

Indoor Unit

AOTV09LAC

AOTV09LAC

Outdoor Unit

AR-RAC1E

AR-RAC1E

Wireless Remote Controller

Optional Parts

UTB-TUD

UTB-TUD

Wired Remote Controller

UTY-RVNYN

UTY-RVNYN

Wired Remote Controller - Backlit Wired Controller

WHITE BOX

UTY-XWZX

External Connect Kit

Key features

These units are installed to sit on the floor when wall space is limited.

  • 10 Degree Heat
    10°C Heat Operation

    The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.

  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

  • Apple Catechin Filter
    Apple-Catechin Filter

    Fine dust, invisible mould spores and harmful microorganisms are absorbed onto the filter by static electricity and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Shut Louvre
    Auto Shut Louvre

    The auto shut louvres close or open automatically when the unit stops or starts.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Automatic Air Flow Adjustment
    Automatic Air Flow Adjustment

    The micro-processor automatically adjusts the air flow to follow changes in room temperature.

  • Automatic Louvre
    Automatic Louvre

    The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Long Life Ion Deodorisation Filter
    Long-Life Ion Deodorisation Filter

    The filter deodorises by powerfully decomposing absorbed odours using the oxidising and reducing effects of ion generated by the ultra-fine particle ceramic.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Sleep Timer
    Sleep Timer

    The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

  • Super Quiet Mode
    Super Quiet Mode

    The indoor units fan can operate at a low speed to produce quieter operation.

  • Up Down Swing
    Up/Down Swing Louvre

    The up/down louvre automatically swings up and down.

  • v-PAM
    V-PAM

    v-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.

  • Washable Panel
    Washable Panel

    Dust that accumulates on the air conditioner can be easily cleaned with a damp cloth.

  • Coil Dry
    Coil Dry

    Runs the indoor fan on ultra low speed to dry the inside of the heat pump. This helps prevent the growth of mould and bacteria.

Operating Manual

Click on the Download button below to get the pdf

Download PDF

This product is part of the Residential and Commercial Floor Console range

Back to Residential Floor Console range Back to Commercial Floor Console range
Get a Fujitsu Air Conditioner

Get a Quote

Find where to buy a Fujitsu General Heat Pump / Air Conditioner