Take control. Controller options.
This range is compatible with the following controller options.
Lifestyle Range
Energy-efficient wall mounted units. A stylish design, along with efficient features like Human Sensor Control and Economy mode have been combined to offer user flexibility and total control around the comfort of their home.
Type | Split System |
Available in | Reverse Cycle - 2.0kW, 2.5kW, 3.5kW, 4.2kW, 5.0kW, 6.0kW, 7.1kW, 8.5kW, 9.4kW, 9.5kW |
Refrigerant | R32 |
The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
With All DC, electricity loss is decreased and power consumption reduced.
Fine dust, invisible mould spores and harmful microorganisms are absorbed onto the filter by static electricity and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.
Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.
The auto shut louvres close or open automatically when the unit stops or starts.
The unit automatically switches between operating modes based on the temperature setting and room temperature.
The micro-processor automatically adjusts the air flow to follow changes in room temperature.
The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.
Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.
Limits the maximum operation current, and performs operation with the power consumption suppressed.
Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.
Human sensor detects movement of people within the conditioned room.
i-PAM inverter technology enables high output and high efficiency performance.
The filter deodorises by powerfully decomposing absorbed odours using the oxidising and reducing effects of ion generated by the ultra-fine particle ceramic.
The compressor speed and the outdoor unit fan speed are limited to reduce the operational noise.
ON-OFF timer can be set to operate once every 24 hours.
Powerful mode will operate the indoor unit fan and outdoor unit compressor at maximum operation to quickly make the room conditioned and comfortable.
This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.
The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.
The indoor units fan can operate at a low speed to produce quieter operation.
The up/down louvre automatically swings up and down.
v-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.
Dust that accumulates on the air conditioner can be easily cleaned with a damp cloth.
Weekly + setback timer can set temperature for two time spans and for each day of the week.
Different ON-OFF times can be set for up to 7 days.
This range is compatible with the following controller options.
The economy operation will save energy in heating, cooling and dry mode and is set by pressing the button on the remote control.
The compressor speed and the outdoor unit fan speed are limited to reduce the operational noise.
The room temperature can be set to go no lower than 10°C, ensuring that the room does not get too cold when not occupied. Perfect for cold climates.
This mode will operate the air conditioner at maximum capacity for 20 minutes, providing comfort faster than ever before.
Different ON-OFF times can be set for up to 7 days.
The room temperature can be set to go no lower than 10°C, ensuring that the room does not get too cold when not occupied. Perfect for cold climates.
With Artificial Intelligence (AI) and based on your air conditioner usage, the app will remind you to clean your filters at certain intervals
Program rules so that your air conditioner turns on automatically once the room goes above or below certain temperatures
Use geolocation to automatically turn your air conditioner on or off based on your proximity to home
For further information on this adapter see here
Attribute | ASTH07KMCD 2.00kW(C) 2.80kW(H) View model | ASTH09KMCD 2.50kW(C) 3.20kW(H) View model | ASTG09KMTC 2.50kW(C) 3.20kW(H) View model | ASTH12KMCD 3.50kW(C) 3.70kW(H) View model | ASTG12KMTC 3.50kW(C) 3.70kW(H) View model | ASTH14KMCD 4.20kW(C) 5.40kW(H) View model | ASTG18KMTC 5.00kW(C) 6.00kW(H) View model | ASTH18KMTD 5.00kW(C) 6.00kW(H) View model | ASTG22KMTC 6.00kW(C) 7.20kW(H) View model | ASTH22KMTD 6.00kW(C) 7.20kW(H) View model | ASTG24KMTC 7.10kW(C) 8.00kW(H) View model | ASTH24KMTD 7.10kW(C) 8.00kW(H) View model | ASTG30KMTC 8.50kW(C) 9.00kW(H) View model | ASTH30KMTD 8.50kW(C) 9.00kW(H) View model | ASTG34KMTC 9.40kW(C) 10.30kW(H) View model | ASTH34KMTD 9.50kW(C) 10.30kW(H) View model |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Operation Type
|
Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle |
Power Source
V/Ph/Hz
|
230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 |
Cooling Capacity
kW (Rated (Min - Max))
|
2.00 (0.9 - 3.5) | 2.50 (0.8 - 3.6) | 2.50 (0.8 - 3.6) | 3.50 (0.8 - 4.1) | 3.50 (0.8 - 4.1) | 4.20 (0.9 - 4.5) | 5.00 (1 - 6.5) | 5.00 (1 - 6.5) | 6.00 (1.1 - 7.5) | 6.00 (1.1 - 7.5) | 7.10 (1.1 - 8.3) | 7.10 (1.1 - 8.3) | 8.50 (2.9 - 10.5) | 8.50 (2.9 - 10.5) | 9.40 (2.9 - 11.2) | 9.50 (2.9 - 11.2) |
Heating Capacity
kW (Rated (Min - Max))
|
2.80 (0.9 - 4.5) | 3.20 (0.9 - 5.3) | 3.20 (0.9 - 5.3) | 3.70 (0.9 - 6.1) | 3.70 (0.9 - 6.1) | 5.40 (0.9 - 6.9) | 6.00 (1.05 - 8.7) | 6.00 (1.05 - 8.7) | 7.20 (1.1 - 9.4) | 7.20 (1.1 - 9.4) | 8.00 (1.1 - 10.1) | 8.00 (1.1 - 10.1) | 9.00 (2.2 - 11.2) | 9.00 (2.7 - 11.2) | 10.30 (2.7 - 11.7) | 10.30 (2.9 - 11.7) |
Input Power Cooling
kW (Rated (Min - Max))
|
0.4 (0.25 - 1.15) | 0.53 (0.15 - 1.04) | 0.53 (0.15 - 1.04) | 0.86 (0.15 - 1.29) | 0.89 (0.15 - 1.29) | 1.15 (0.25 - 1.25) | 1.16 (0.24 - 1.68) | 1.16 (0.24 - 1.93) | 1.58 (0.24 - 2.3) | 1.58 (0.24 - 2.72) | 2.08 (0.24 - 3.15) | 2.08 (0.24 - 3.15) | 2.46 (0.58 - 3.85) | 2.49 (0.6 - 4) | 2.78 (0.59 - 4.03) | 2.72 (0.66 - 4.2) |
Input Power Heating
kW (Rated (Min - Max))
|
0.58 (0.25 - 1.3) | 0.66 (0.25 - 1.61) | 0.66 (0.25 - 1.61) | 0.81 (0.25 - 1.89) | 0.79 (0.25 - 1.89) | 1.4 (0.25 - 2.05) | 1.28 (0.14 - 2.42) | 1.28 (0.14 - 2.75) | 1.7 (0.14 - 2.63) | 1.7 (0.14 - 2.75) | 1.91 (0.14 - 3) | 1.91 (0.14 - 3.17) | 2.34 (0.5 - 4.01) | 2.39 (0.48 - 3.6) | 2.84 (0.6 - 4.24) | 3.04 (0.68 - 3.8) |
EER Cooling
kW/kW
|
5 | 4.71 | 4.71 | 4.07 | 3.93 | 3.65 | 4.31 | 4.31 | 3.8 | 3.8 | 3.41 | 3.41 | 3.45 | 3.41 | 3.38 | 3.49 |
COP Heating
kW/kW
|
4.83 | 4.84 | 4.84 | 4.57 | 4.68 | 3.86 | 4.69 | 4.69 | 4.24 | 4.24 | 4.19 | 4.19 | 3.84 | 3.77 | 3.63 | 3.39 |
Star Rating Cooling
(0-10) (Hot / Average / Cold)
|
5.5 / 5 / 5.5 | 5.5 / 5 / 5.5 | 5.5 / 5 / 5.5 | 5 / 4.5 / 5 | 4.5 / 4.5 / 5 | 4 / 4 / 4 | 4.5 / 4.5 / 4.5 | 5 / 4.5 / 5 | 4 / 4 / 4 | 4.5 / 4 / 4.5 | 3.5 / 3.5 / 3.5 | 3.5 / 3.5 / 3.5 | 3 / 2.5 / 2.5 | 4 / 3.5 / 4 | 3 / 2.5 / 2.5 | 4 / 3.5 / 4 |
Star Rating Heating
(0-10) (Hot / Average / Cold)
|
4 / 3.5 / 3 | 3.5 / 3.5 / 3 | 3.5 / 3 / 3 | 3.5 / 3 / 2.5 | 3.5 / 3 / 2.5 | 3.5 / 2.5 / 2 | 3.0 / 2.5 / 2.5 | 3.5 / 3 / 2.5 | 3 / 2.5 / 2 | 3 / 2.5 / 2 | 3 / 2.5 / 2 | 3 / 2.5 / 2 | 2.5 / 2 / 2 | 4 / 3 / 2 | 2 / 2 / 1.5 | 3.5 / 2.5 / 1.5 |
Total Cooling Seasonal Performance Factor Residential
kW (Hot / Average / Cold)
|
7.296 / 6.734 / 7.007 | 7.193 / 6.68 / 7.049 | 7.219 / 6.755 / 7.155 | 6.545 / 6.108 / 6.521 | 6.477 / 6.193 / 6.625 | 5.834 / 5.513 / 5.926 | 6.46 / 6.102 / 6.472 | 6.652 / 6.3 / 6.726 | 5.852 / 5.558 / 5.943 | 6.009 / 5.714 / 6.146 | 5.307 / 5.039 / 5.4 | 5.344 / 5.094 / 5.481 | 4.658 / 4.334 / 4.477 | 5.56 / 5.284 / 5.716 | 4.628 / 4.317 / 4.482 | 5.501 / 5.242 / 5.633 |
Heating Seasonal Performance Factor Residential
kW (Hot / Average / Cold)
|
5.504 / 5.042 / 4.506 | 5.455 / 5.025 / 4.533 | 5.36 / 4.975 / 4.548 | 5.014 / 4.621 / 4.072 | 5.241 / 4.817 / 4.278 | 5.09 / 4.383 / 3.677 | 4.704 / 4.48 / 4.092 | 5.004 / 4.676 / 4.181 | 4.609 / 4.194 / 3.605 | 4.64 / 4.258 / 3.722 | 4.779 / 4.212 / 3.525 | 4.819 / 4.265 / 3.586 | 4.111 / 3.856 / 3.546 | 5.55 / 4.534 / 3.841 | 3.834 / 3.603 / 3.312 | 5.079 / 4.1 / 3.474 |
Total Cooling Seasonal Performance Factor Commercial
kW (Hot / Average / Cold)
|
8.432 / 9.047 / 10.78 | 8.179 / 8.728 / 10.148 | 8.198 / 8.777 / 10.227 | 7.613 / 8.312 / 10.07 | 7.443 / 8.666 / 10.522 | 6.511 / 6.962 / 7.93 | 7.156 / 7.555 / 8.512 | 7.428 / 7.934 / 9.086 | 6.45 / 6.834 / 7.655 | 6.672 / 7.138 / 8.111 | 5.873 / 6.234 / 7.03 | 5.873 / 6.231 / 6.897 | 5.097 / 5.258 / 5.782 | 6.233 / 6.729 / 7.766 | 5.018 / 5.153 / 5.599 | 6.118 / 6.566 / 7.494 |
Heating Seasonal Performance Factor Commercial
kW (Hot / Average / Cold)
|
5.499 / 5.215 / 4.757 | 5.448 / 5.183 / 4.761 | 5.351 / 5.112 / 4.744 | 5.005 / 4.759 / 4.304 | 5.234 / 4.971 / 4.518 | 5.105 / 4.676 / 4.06 | 4.684 / 4.533 / 4.216 | 4.631 / 4.393 / 4.376 | 4.6 / 4.34 / 3.859 | 4.631 / 4.393 / 3.951 | 4.775 / 4.421 / 3.856 | 4.817 / 4.474 / 3.909 | 4.1 / 3.939 / 3.678 | 5.611 / 5.02 / 4.353 | 3.823 / 3.676 / 3.433 | 5.161 / 4.58 / 3.964 |
Running Current
amps (Cooling / Heating)
|
2.4 / 3.2 | 3 / 3.5 | 3 / 3.5 | 4.2 / 4 | 4.2 / 4 | 5.1 / 6.2 | 5.1 / 5.6 | 5.3 / 5.8 | 6.8 / 7.4 | 7.1 / 7.7 | 8.9 / 8.3 | 9.3 / 8.7 | 10.4 / 10.1 | 11 / 10.6 | 11.7 / 11.9 | 12 / 13.4 |
Moisture Removal
l/hr
|
0.8 | 1 | 0.3 | 1.2 | 1 | 1.6 | 1.3 | 1.3 | 2.3 | 2.3 | 2.7 | 2.7 | 2.5 | 4.4 | 3.5 | 4.9 |
Indoor Sound Pressure Cooling
dBA (High / Quiet)
|
40 / 20 | 40 / 19 | 40 / 19 | 40 / 19 | 40 / 19 | 44 / 20 | 46 / 29 | 46 / 29 | 48 / 29 | 48 / 29 | 49 / 29 | 49 / 29 | 51 / 33 | 51 / 32 | 52 / 34 | 51 / 34 |
Indoor Sound Pressure Heating
dBA (High / Quiet)
|
42 / 22 | 40 / 21 | 40 / 21 | 42 / 21 | 42 / 21 | 45 / 24 | 46 / 29 | 46 / 29 | 48 / 29 | 48 / 29 | 49 / 29 | 49 / 29 | 51 / 33 | 48 / 32 | 51 / 33 | 51 / 33 |
Outdoor Sound Pressure
dBA (Cooling / Heating)
|
50 / 50 | 46 / 46 | 46 / 46 | 49 / 49 | 49 / 49 | 50 / 50 | 47 / 48 | 47 / 49 | 49 / 52 | 49 / 52 | 54 / 52 | 54 / 53 | 50 / 54 | 53 / 55 | 50 / 54 | 58 / 59 |
Outdoor Sound Power
dBA
|
60 | 56 | 55 | 60 | 59 | 65 | 59 | 59 | 61 | 61 | 66 | 66 | 66 | 65 | 65 | 70 |
Air Circulation (Indoor - High Fan) Cooling
l/sec
|
194 | 194 | 194 | 194 | 194 | 214 | 283 | 283 | 294 | 294 | 325 | 325 | 389 | 381 | 389 | 381 |
Air Circulation (Indoor - High Fan) Heating
l/sec
|
217 | 197 | 197 | 214 | 214 | 228 | 283 | 286 | 294 | 300 | 325 | 331 | 389 | 350 | 389 | 372 |
Indoor Unit Dimensions
mm (Height x Width x Depth)
|
270 x 834 x 222 | 270 x 834 x 222 | 270 x 834 x 222 | 270 x 834 x 222 | 270 x 834 x 222 | 270 x 834 x 222 | 280 x 980 x 240 | 280 x 980 x 240 | 280 x 980 x 240 | 280 x 980 x 240 | 280 x 980 x 240 | 280 x 980 x 240 | 340 x 1150 x 280 | 340 x 1150 x 280 | 340 x 1150 x 280 | 340 x 1150 x 280 |
Indoor Unit Weight
kg
|
10.00 | 10.00 | 10.00 | 10.00 | 10.00 | 10.00 | 12.50 | 12.50 | 12.50 | 12.50 | 12.50 | 12.50 | 18.50 | 16.50 | 18.00 | 16.50 |
Outdoor Unit Dimensions
mm (Height x Width x Depth)
|
- | - | 542 x 799 x 290 | - | 542 x 799 x 290 | - | 716 x 820 x 315 | 716 x 820 x 315 | 716 x 820 x 315 | 716 x 820 x 315 | 716 x 820 x 315 | 716 x 820 x 315 | 830 x 900 x 330 | - | 914 x 970 x 370 | - |
Outdoor Unit Weight
kg
|
25.00 | 32.00 | 32.00 | 32.00 | 32.00 | 34.00 | 42.00 | 42.00 | 42.00 | 42.00 | 42.00 | 42.00 | 60.00 | 60.00 | 74.00 | 74.00 |
Piping Connects
mm Ø (Liquid / Gas)
|
6.35 / 9.52 | 6.36 / 10.52 | 6.35 / 9.52 | 6.37 / 11.52 | 6.35 / 9.52 | 6.38 / 9.52 | 6.35 / 12.7 | 6.35 / 12.7 | 6.35 / 12.7 | 6.35 / 12.7 | 6.35 / 12.7 | 6.35 / 12.7 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 |
Pipe Length
m (Max (Precharged))
|
20 (15) | 20 (15) | 20 (15) | 20 (15) | 20 (15) | 20 (15) | 30 (15) | 30 (15) | 30 (15) | 30 (15) | 30 (15) | 30 (15) | 75 (20) | 50 (20) | 75 (30) | 50 (25) |
Max Height Difference
m
|
15 | 15 | 15 | 15 | 15 | 15 | 25 | 25 | 25 | 25 | 25 | 25 | 30 | 30 | 30 | 30 |
Operation Range Cooling
°CDB (Min to Max)
|
-10 to 50 | -10 to 50 | -10 to 46 | -10 to 50 | -10 to 46 | -10 to 50 | -10 to 46 | -10 to 50 | -10 to 46 | -10 to 50 | -10 to 46 | -10 to 50 | -10 to 46 | -10 to 50 | -10 to 46 | -10 to 50 |
Operation Range Heating
°CDB (Min to Max)
|
-15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 |
Refrigerant Type
|
R32 | - | R32 | - | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 |
Refrigerant Amount
g
|
700 | 850 | 850 | 850 | 850 | 940 | 1,320 | 1,270 | 1,320 | 1,270 | 1,320 | - | 1,650 | 1,700 | 2,000 | 2,300 |
Purchase from a Fujitsu accredited installer and receive a full 6 year warranty.
Explore nowVoted by New Zealanders as a trusted brand in the heat pump category.
Explore nowAccess high-level support from our in-house customer care and technical support department.
Find out MoreWe have a comprehensive network of Fujitsu Accredited Installers right across New Zealand to ensure that there is a local stockist in your area to assist you wherever you are.
Find a StockistHelpful articles and tips on how to keep your home and office comfortable all year round.