ABTG1824LVTALVTC
Product Category Floor/Ceiling Consoles
Product Range Floor/Ceiling Dual Console range
Capacity 7.10kW Cooling 8.00kW Heating
Model Number ABTG24LVTC
Room Size Medium Room

Technical Specifications

Indoor unit ABTG24LVTC
Outdoor unit AOTG24LATC
Operation Type Reverse Cycle
Power Source V/Ph/Hz 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max)) 7.10 (2.9 - 8.0)
Heating Capacity kW (Rated (Min - Max)) 8.00 (2.2 - 9.1)
Input Power Cooling kW (Rated (Max)) 2.14 (2.40)
Input Power Heating kW (Rated (Max)) 2.21 (2.65)
EER Cooling kW/kW 3.32
COP Heating kW/kW 3.61
Star Rating Cooling (0-10) (Hot / Average / Cold) 2.0 / 2.0 / 2.0
Star Rating Heating (0-10) (Hot / Average / Cold) 2.5 / 2.0 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 3.863 / 3.564 / 3.599
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.472 / 3.827 / 3.237
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.086 / 4.040 / 4.246
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.478 / 4.099 / 3.470
Running Current amps (Cooling / Heating) 9.0 / 9.3
Moisture Removal l/hr 2.7
Indoor Sound Pressure Cooling dBA (High / Quiet) 49 / 36
Indoor Sound Pressure Heating dBA (High / Quiet) 49 / 36
Outdoor Sound Pressure dBA (Cooling / Heating) 53 / 54
Outdoor Sound Power dBA 68
Air Circulation (Indoor - High Fan) Cooling l/sec 272
Air Circulation (Indoor - High Fan) Heating l/sec 272
Indoor Unit Dimensions mm (Height x Width x Depth) 199 x 990 x 655
Indoor Unit Weight kg 27.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 830 x 900 x 330
Outdoor Unit Weight kg 60.00
Piping Connects mm Ø (Liquid / Gas) 6.35 / 15.88
Pipe Length m (Max (Precharged)) 30 (20)
Max Height Difference m 30
Operation Range Cooling °CDB (Min to Max) -10 to 46
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Type R410A
Refrigerant Amount g 2,100

Dimensions

What’s included in your purchase

ABTG1824LVTALVTC

ABTG24LVTC

Indoor Unit

AOTG24LATC

Outdoor Unit

AR-RAH2E

Wireless Remote Controller

Optional Parts

anywair-short

IS-IR-WIFI-FG

WiFi Control - anywAiR Technology Wi-Fi Device

UTY-RNNYN

UTY-RNNYN

Wired Remote Controller

UTY-RSNYN

UTY-RSNYN

Wired Remote Controller - Simple Controller With Mode Button

UTY-RVNYN

UTY-RVNYN

Wired Remote Controller - Backlit Wired Controller

WHITE BOX

UTY-XWZX

External Connect Kit

Key features

Offers the flexibility of being easily installed on the floor or under the ceiling.

  • 10 Degree Heat
    10°C Heat Operation

    The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.

  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Shut Louvre
    Auto Shut Louvre

    The auto shut louvres close or open automatically when the unit stops or starts.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Automatic Air Flow Adjustment
    Automatic Air Flow Adjustment

    The micro-processor automatically adjusts the air flow to follow changes in room temperature.

  • Automatic Louvre
    Automatic Louvre

    The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Double Swing Automatic
    Double Swing Automatic

    Complex swing action of the louvres enables them to swing automatically in both horizontal and vertical directions.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Removable Intake Grill
    Removable Intake Grill

    The indoor unit’s intake grille can be removed for easy cleaning and maintenance.

  • Right Left Swing
    Right / Left Swing Louvre

    The right/left louvre automatically swings in either direction.

  • Sleep Timer
    Sleep Timer

    The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

  • Up Down Swing
    Up/Down Swing Louvre

    The up/down louvre automatically swings up and down.

  • v-PAM
    V-PAM

    v-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.

  • Weekly Setback Timer
    Weekly + Setback Timer

    Weekly + setback timer can set temperature for two time spans and for each day of the week.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

Operating Manual

Click on the Download button below to get the pdf

Download PDF

This product is part of the Residential and Commercial Floor/Ceiling Dual Console range

Back to Residential Floor/Ceiling Dual Console range Back to Commercial Floor/Ceiling Dual Console range
Get a Fujitsu Air Conditioner

Get a Quote

Find where to buy a Fujitsu General Heat Pump / Air Conditioner

map-icon-white Find a Stockist